MICRODUCT ACCESSORIES LUBRICANT & CLEANING
Tools for installing fibre cable and blown fibre into microduct using compressed air, also called blowing or jetting. The technology is time-saving, well-proven, accepted and offers many technical and quality advantages compared to traditional cable pulling, especially in the deployment of FTTx networks. Melbye has over 20 years of experience in this installation method and can assist with training, service and support.
USE Microduct Deployment
CODE
DESCRIPTION
1693890 1693891 1693892 1693893 1693894 1693895 1693896 1693897 1693898 1693899
PRELUBE 5000 240ml MICROCABLE BLOWING LUBRICANT
PRELUBE 2000 0,95l PRELUBE 2000 3,8l
PRELUBE 2000 WINTERGRADE 0,95l PRELUBE 2000 WINTERGRADE 3,8l
LUBRICANT F 0,95l LUBRICANT F 3,8l
LUBRICANT F WINTERGRADE 3,8l LUBRICANT WIPES FTTX, 20 PCS LUBRICANT SPRAY FTTX 0,95l
INSTRUCTIONS - CLEANING & LUBRICATING
It is very important to clean the microduct before you start fibre blowing so that it is free of dirt, water and moisture. Cleaning in advance will achieve a smoother installation and can save you unnecessary costs and time.
To clean the microduct, sponges must be blown through:
1. Place one or more sponges into the microduct. 2. Apply air pressure and blow the sponge through. 3. Check that the sponge is clean when it exits the other end. To considerably increase the blowing distance, sponges can also be used to smooth out the lubricant before you start blowing. Refer to the lubricant’s packaging to ensure that you use a lubricant that is suitable for the microduct dimension and length to be blown.